{"status":"OK","data":{"id":11498,"identifier":"YWGTJN","persistentUrl":"https://doi.org/10.34894/YWGTJN","protocol":"doi","authority":"10.34894","separator":"/","publisher":"DataverseNL","publicationDate":"2018-10-22","storageIdentifier":"surf://10411/UA6UZG","effectiveDatasetFileCountLimit":10000,"datasetFileUploadsAvailable":9991,"datasetType":"dataset","locks":[],"latestVersion":{"id":1272,"datasetId":11498,"datasetPersistentId":"doi:10.34894/YWGTJN","datasetType":"dataset","storageIdentifier":"surf://10411/UA6UZG","versionNumber":1,"internalVersionNumber":6,"versionMinorNumber":0,"versionState":"RELEASED","latestVersionPublishingState":"RELEASED","deaccessionLink":"","lastUpdateTime":"2018-10-22T16:07:16Z","releaseTime":"2018-10-22T16:07:16Z","createTime":"2018-06-11T15:24:06Z","alternativePersistentId":"hdl:10411/UA6UZG","publicationDate":"2018-10-22","citationDate":"2018-10-22","effectiveDatasetFileCountLimit":10000,"datasetFileUploadsAvailable":9991,"license":{"name":"CC0-1.0","uri":"http://creativecommons.org/publicdomain/zero/1.0","iconUri":"https://licensebuttons.net/p/zero/1.0/88x31.png","rightsIdentifier":"CC0-1.0","rightsIdentifierScheme":"SPDX","schemeUri":"https://spdx.org/licenses/","languageCode":"en"},"fileAccessRequest":false,"metadataBlocks":{"citation":{"displayName":"Citation Metadata","name":"citation","fields":[{"typeName":"title","multiple":false,"typeClass":"primitive","value":"Replication data for: SICT: automated detection and supervised inspection of fast Ca2+ transients"},{"typeName":"author","multiple":true,"typeClass":"compound","value":[{"authorName":{"typeName":"authorName","multiple":false,"typeClass":"primitive","value":"Groffen, AJA"},"authorAffiliation":{"typeName":"authorAffiliation","multiple":false,"typeClass":"primitive","value":"Vrije Universiteit Amsterdam"}}]},{"typeName":"datasetContact","multiple":true,"typeClass":"compound","value":[{"datasetContactName":{"typeName":"datasetContactName","multiple":false,"typeClass":"primitive","value":"Groffen, AJA"},"datasetContactAffiliation":{"typeName":"datasetContactAffiliation","multiple":false,"typeClass":"primitive","value":"Vrije Universiteit Amsterdam"}}]},{"typeName":"dsDescription","multiple":true,"typeClass":"compound","value":[{"dsDescriptionValue":{"typeName":"dsDescriptionValue","multiple":false,"typeClass":"primitive","value":"Replication data for the manuscript titled \"SICT: automated detection and supervised inspection of fast Ca2+ transients\""},"dsDescriptionDate":{"typeName":"dsDescriptionDate","multiple":false,"typeClass":"primitive","value":"2018-06-11"}}]},{"typeName":"subject","multiple":true,"typeClass":"controlledVocabulary","value":["Computer and Information Science","Medicine, Health and Life Sciences"]},{"typeName":"keyword","multiple":true,"typeClass":"compound","value":[{"keywordValue":{"typeName":"keywordValue","multiple":false,"typeClass":"primitive","value":"Ca2+ imaging"}}]},{"typeName":"depositor","multiple":false,"typeClass":"primitive","value":"Groffen, AJA"},{"typeName":"dateOfDeposit","multiple":false,"typeClass":"primitive","value":"2018-06-11"}]},"dansDataVaultMetadata":{"displayName":"Data Vault Metadata","name":"dansDataVaultMetadata","fields":[{"typeName":"dansDataversePid","multiple":false,"typeClass":"primitive","value":"doi:10.34894/YWGTJN"},{"typeName":"dansDataversePidVersion","multiple":false,"typeClass":"primitive","value":"1.0"},{"typeName":"dansBagId","multiple":false,"typeClass":"primitive","value":"urn:uuid:8ae09e12-52ac-48ec-b1d5-f77485dfa43f"},{"typeName":"dansNbn","multiple":false,"typeClass":"primitive","value":"urn:nbn:nl:ui:13-d1dca107-ed7a-41e0-b296-574ed5241510"}]}},"files":[{"description":"Patch-clamp recording acquired with ClampEx  and saved in ABF2 format. Data were recorded simultaneously with Ca2+ imaging.","label":"RM20160705_816patch_v1l1_35_ap0001.abf","restricted":false,"version":1,"datasetVersionId":1272,"dataFile":{"id":11503,"persistentId":"","filename":"RM20160705_816patch_v1l1_35_ap0001.abf","contentType":"application/octet-stream","friendlyType":"Unknown","filesize":487424,"description":"Patch-clamp recording acquired with ClampEx  and saved in ABF2 format. Data were recorded simultaneously with Ca2+ imaging.","storageIdentifier":"surf://store:163f33ec2a5-ce3037d481ca","rootDataFileId":-1,"checksum":{"type":"SHA-1","value":"64c086861b809ae4c3254f09cb59861b1f342457"},"tabularData":false,"creationDate":"2018-06-12","publicationDate":"2018-10-22","lastUpdateTime":"2018-10-22T16:07:16Z","fileAccessRequest":false}},{"description":"Metadata file to accompany the RAW file with the same name. This file contains image acquisition times for each frame in the time lapse. In addition, it contains many other experimental parameters. ","label":"RM20160705_816patch_v1l1_35_ap0001.mtd","restricted":false,"version":2,"datasetVersionId":1272,"dataFile":{"id":11504,"persistentId":"","filename":"RM20160705_816patch_v1l1_35_ap0001.mtd","contentType":"application/octet-stream","friendlyType":"Unknown","filesize":166132,"description":"Metadata file to accompany the RAW file with the same name. This file contains image acquisition times for each frame in the time lapse. In addition, it contains many other experimental parameters. ","storageIdentifier":"surf://store:163f33ec6c7-994b8745cc31","rootDataFileId":-1,"checksum":{"type":"SHA-1","value":"f8e71b58b3e0a3281e6edfc4025ea298b1c68e10"},"tabularData":false,"creationDate":"2018-06-12","publicationDate":"2018-10-22","lastUpdateTime":"2018-10-22T16:07:16Z","fileAccessRequest":false}},{"description":"An example input file for the Supervised Inspection of Calcium Transients with the SICT program. A neuron expressing the fluorescent Ca2+ indicator GCaMP6f was visualized with a 40x-oil immersion objective (Olympus UAPON40xO340-2, NA 1.35). Images were acquired using an Andor Ixon Ultra 897 EM-CCD camera by Live Acquisition software (FEI) at a frequency of 28.77 Hz. The cell was held in whole cell patch clamp at a resting potential of -70 mV. A stimulation was given to measure the Ca2+ response during a single action potential. For more details, see online methods.","label":"RM20160705_816patch_v1l1_35_ap0001.raw","restricted":false,"version":2,"datasetVersionId":1272,"dataFile":{"id":11505,"persistentId":"","filename":"RM20160705_816patch_v1l1_35_ap0001.raw","contentType":"image/RAW","friendlyType":"Bitmap Image","filesize":378535936,"description":"An example input file for the Supervised Inspection of Calcium Transients with the SICT program. A neuron expressing the fluorescent Ca2+ indicator GCaMP6f was visualized with a 40x-oil immersion objective (Olympus UAPON40xO340-2, NA 1.35). Images were acquired using an Andor Ixon Ultra 897 EM-CCD camera by Live Acquisition software (FEI) at a frequency of 28.77 Hz. The cell was held in whole cell patch clamp at a resting potential of -70 mV. A stimulation was given to measure the Ca2+ response during a single action potential. For more details, see online methods.","storageIdentifier":"surf://store:163f33f2a9d-e65ca8b4d153","rootDataFileId":-1,"checksum":{"type":"SHA-1","value":"8e10ab06d402a367d9f438cde962f050d13fa43a"},"tabularData":false,"creationDate":"2018-06-12","publicationDate":"2018-10-22","lastUpdateTime":"2018-10-22T16:07:16Z","fileAccessRequest":false}},{"description":"An example input file for the Supervised Inspection of Calcium Transients with the SICT program. A neuron expressing the fluorescent Ca2+ indicator GCaMP6f was visualized with a 40x-oil immersion objective (Olympus UAPON40xO340-2, NA 1.35). Images were acquired using an Andor Ixon Ultra 897 EM-CCD camera by Live Acquisition software (FEI) at a frequency of 28.77 Hz. The cell was held in whole cell patch clamp at a resting potential of -70 mV without stimulation. For more details, see online methods. ","label":"RM20160907_816patch_v1l2_36_m0001.raw","restricted":false,"version":1,"datasetVersionId":1272,"dataFile":{"id":11499,"persistentId":"","filename":"RM20160907_816patch_v1l2_36_m0001.raw","contentType":"image/RAW","friendlyType":"Bitmap Image","filesize":1572864000,"description":"An example input file for the Supervised Inspection of Calcium Transients with the SICT program. A neuron expressing the fluorescent Ca2+ indicator GCaMP6f was visualized with a 40x-oil immersion objective (Olympus UAPON40xO340-2, NA 1.35). Images were acquired using an Andor Ixon Ultra 897 EM-CCD camera by Live Acquisition software (FEI) at a frequency of 28.77 Hz. The cell was held in whole cell patch clamp at a resting potential of -70 mV without stimulation. For more details, see online methods. ","storageIdentifier":"surf://store:163f2e097f1-3318a0c43d55","rootDataFileId":-1,"checksum":{"type":"SHA-1","value":"a3d5b21edec77f81babb96112f7ad16cdb44822d"},"tabularData":false,"creationDate":"2018-06-12","publicationDate":"2018-10-22","lastUpdateTime":"2018-10-22T16:07:16Z","fileAccessRequest":false}},{"description":"An example input file for the Supervised Inspection of Calcium Transients with the SICT program. A neuron expressing the fluorescent Ca2+ indicator GCaMP6f was visualized with a 40x-oil immersion objective (Olympus UAPON40xO340-2, NA 1.35). Images were acquired using an Andor Ixon Ultra 897 EM-CCD camera by Live Acquisition software (FEI) at a frequency of 28.77 Hz. The cell was held in whole cell patch clamp at a resting potential of -70 mV. A stimulation was given to measure the Ca2+ response during a single action potential. For more details, see online methods. ","label":"RM20160907_816patch_v1l2_37_AP0002.raw","restricted":false,"version":1,"datasetVersionId":1272,"dataFile":{"id":11500,"persistentId":"","filename":"RM20160907_816patch_v1l2_37_AP0002.raw","contentType":"image/RAW","friendlyType":"Bitmap Image","filesize":487587840,"description":"An example input file for the Supervised Inspection of Calcium Transients with the SICT program. A neuron expressing the fluorescent Ca2+ indicator GCaMP6f was visualized with a 40x-oil immersion objective (Olympus UAPON40xO340-2, NA 1.35). Images were acquired using an Andor Ixon Ultra 897 EM-CCD camera by Live Acquisition software (FEI) at a frequency of 28.77 Hz. The cell was held in whole cell patch clamp at a resting potential of -70 mV. A stimulation was given to measure the Ca2+ response during a single action potential. For more details, see online methods. ","storageIdentifier":"surf://store:163f2e0fa24-fbfe632cb340","rootDataFileId":-1,"checksum":{"type":"SHA-1","value":"9f467caeba80d75a94262c5be983d1a446042a93"},"tabularData":false,"creationDate":"2018-06-12","publicationDate":"2018-10-22","lastUpdateTime":"2018-10-22T16:07:16Z","fileAccessRequest":false}},{"description":"An example input file for the Supervised Inspection of Calcium Transients with the SICT program. A neuron expressing the fluorescent Ca2+ indicator GCaMP6f was visualized with a 40x-oil immersion objective (Olympus UAPON40xO340-2, NA 1.35). Images were acquired using an Andor Ixon Ultra 897 EM-CCD camera by Live Acquisition software (FEI) at a frequency of 28.77 Hz. The cell was held in whole cell patch clamp at a resting potential of -70 mV without stimulation. For more details, see online methods. ","label":"RM20161101_898pch_v2l4_10_m0000.raw","restricted":false,"version":1,"datasetVersionId":1272,"dataFile":{"id":11501,"persistentId":"","filename":"RM20161101_898pch_v2l4_10_m0000.raw","contentType":"image/RAW","friendlyType":"Bitmap Image","filesize":1572864000,"description":"An example input file for the Supervised Inspection of Calcium Transients with the SICT program. A neuron expressing the fluorescent Ca2+ indicator GCaMP6f was visualized with a 40x-oil immersion objective (Olympus UAPON40xO340-2, NA 1.35). Images were acquired using an Andor Ixon Ultra 897 EM-CCD camera by Live Acquisition software (FEI) at a frequency of 28.77 Hz. The cell was held in whole cell patch clamp at a resting potential of -70 mV without stimulation. For more details, see online methods. ","storageIdentifier":"surf://store:163f2e1c28d-3bb55f306c3e","rootDataFileId":-1,"checksum":{"type":"SHA-1","value":"3f79a2ee796206ff5ae8fae7fde2ac18990659ab"},"tabularData":false,"creationDate":"2018-06-12","publicationDate":"2018-10-22","lastUpdateTime":"2018-10-22T16:07:16Z","fileAccessRequest":false}},{"description":"An example input file for the Supervised Inspection of Calcium Transients with the SICT program. A neuron expressing the fluorescent Ca2+ indicator GCaMP6f was visualized with a 40x-oil immersion objective (Olympus UAPON40xO340-2, NA 1.35). Images were acquired using an Andor Ixon Ultra 897 EM-CCD camera by Live Acquisition software (FEI) at a frequency of 28.77 Hz. The cell was held in whole cell patch clamp at a resting potential of -70 mV. A stimulation was given to measure the Ca2+ response during a single action potential. For more details, see online methods. ","label":"RM20161101_898pch_v2l4_11_AP0001.raw","restricted":false,"version":1,"datasetVersionId":1272,"dataFile":{"id":11502,"persistentId":"","filename":"RM20161101_898pch_v2l4_11_AP0001.raw","contentType":"image/RAW","friendlyType":"Bitmap Image","filesize":487587840,"description":"An example input file for the Supervised Inspection of Calcium Transients with the SICT program. A neuron expressing the fluorescent Ca2+ indicator GCaMP6f was visualized with a 40x-oil immersion objective (Olympus UAPON40xO340-2, NA 1.35). Images were acquired using an Andor Ixon Ultra 897 EM-CCD camera by Live Acquisition software (FEI) at a frequency of 28.77 Hz. The cell was held in whole cell patch clamp at a resting potential of -70 mV. A stimulation was given to measure the Ca2+ response during a single action potential. For more details, see online methods. ","storageIdentifier":"surf://store:163f2e2228f-0012ab906d0e","rootDataFileId":-1,"checksum":{"type":"SHA-1","value":"754a8fe73f2bbcfe2841b23d3c57a6010f32cf7a"},"tabularData":false,"creationDate":"2018-06-12","publicationDate":"2018-10-22","lastUpdateTime":"2018-10-22T16:07:16Z","fileAccessRequest":false}},{"description":"Contains custom MATLAB code for the Supervised Inspection of Ca2+ Transients (SICT). Requires MATLAB with the Statistics and Machine Learning Toolbox v11.3, Image Processing Toolbox v10.2 and the Curve Fitting Toolbox 3.5.7. In addition, example files are included for testing the program. Please refer to the user's manual included as supplemental information. ","label":"SICT source code.rar","restricted":false,"version":1,"datasetVersionId":1272,"dataFile":{"id":11506,"persistentId":"","filename":"SICT source code.rar","contentType":"application/x-rar-compressed","friendlyType":"RAR Archive","filesize":120444149,"description":"Contains custom MATLAB code for the Supervised Inspection of Ca2+ Transients (SICT). Requires MATLAB with the Statistics and Machine Learning Toolbox v11.3, Image Processing Toolbox v10.2 and the Curve Fitting Toolbox 3.5.7. In addition, example files are included for testing the program. Please refer to the user's manual included as supplemental information. ","storageIdentifier":"surf://store:163f4b1726b-787161bbe58e","rootDataFileId":-1,"checksum":{"type":"SHA-1","value":"d17b0f3c3e5eca630d4a4cae72ce8bb7c2b832a5"},"tabularData":false,"creationDate":"2018-06-12","publicationDate":"2018-10-22","lastUpdateTime":"2018-10-22T16:07:16Z","fileAccessRequest":false}},{"description":"Supplemetary information containing a user instruction manual","label":"Supplementary information with instruction manual.pdf","restricted":false,"version":1,"datasetVersionId":1272,"dataFile":{"id":12194,"persistentId":"","filename":"Supplementary information with instruction manual.pdf","contentType":"application/pdf","friendlyType":"Adobe PDF","filesize":3464589,"description":"Supplemetary information containing a user instruction manual","storageIdentifier":"surf://store:1665dcb90f3-110f02bc1d02","rootDataFileId":-1,"checksum":{"type":"SHA-1","value":"fd73785da039117b95e5ac741cd9c4ca2369c29c"},"tabularData":false,"creationDate":"2018-10-10","publicationDate":"2018-10-22","lastUpdateTime":"2018-10-22T16:07:16Z","fileAccessRequest":false}}]}}}